Compare Displacement Models
Compare all 10 current visible native listings: eight optical heads, one display/output unit and one communication module. Compare heads using the optical method and their own reference distance, maximum measurement range, resolution and stated linearity interval. The electronic units have separate role-specific tables and are not presented as standalone measuring heads.
Optical sensor heads — 8 models
| Exact model | Listed optical method | Listed reference distance | Listed maximum measurement range | Listed resolution | Listed linearity / stated interval | Listed supply source | Listed laser class | Listed protection / exceptions |
|---|---|---|---|---|---|---|---|---|
| BD-030 | Diffuse reflection | 30mm | 20 to 40mm | 1㎛ | 0.1% F.S. (in 25 to 35mm) | Using power from the amplifier unit. | Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) | IP67 (IEC Standards, except connector of extension cable) |
| BD-030R | Regular reflection | 27.3 mm | 24.9 to 29.7 mm | 1㎛ | ± 0.1% of F.S. | Using power from the amplifier unit. | Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) | IP67 (IEC Standards, except connector of extension cable) |
| BD-065 | Diffuse reflection | 65mm | 50 to 80mm | 2㎛ | 0.1% F.S. (in 55 to 75mm) | Using power from the amplifier unit. | Class 2 (IEC/EN), Class II (FDA(CDRH) CFR Part 1002) | IP67 (IEC Standards, except connector of extension cable) |
| BD-065R | Regular reflection | 62.9 mm | 56.9 to 68.9 mm | 2㎛ | ± 0.1% of F.S. | Using power from the amplifier unit. | Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) | IP67 (IEC Standards, except connector of extension cable) |
| BD-100 | Diffuse reflection | 100mm | 70 to 130mm | 4㎛ | 0.15% F.S. (in 80 to 120mm) | Using power from the amplifier unit. | Class 2 (IEC/EN), Class II (FDA(CDRH) CFR Part 1002) | IP67 (IEC Standards, except connector of extension cable) |
| BD-100R | Regular reflection | 98.3 mm | 86.3 to 110.3 mm | 4㎛ | ± 0.15% of F.S. | Using power from the amplifier unit. | Class 1 (IEC/EN), Class I (FDA(CDRH) CFR Part 1002) | IP67 (IEC Standards, except connector of extension cable) |
| BD-300 | Diffuse reflection | 300mm | 160 ~ 450 mm | 20 ㎛ | ± 0.25% of F.S. | Using power from the amplifier unit. | Class 2 (IEC/EN), Class II (FDA (CDRH) CFR Part 1002) | IP67 (IEC Standards, except connector of extension cable) |
| BD-600 | Diffuse reflection | 600mm | 250 ~ 1,000 mm | 40 ㎛ | ± 0.25% of F.S. (250 ~ 600 mm) ; ± 0.5% of F.S. (600 ~ 1,000 mm) | Using power from the amplifier unit. | Class 2 (IEC/EN), Class II (FDA (CDRH) CFR Part 1002) | IP67 (IEC Standards, except connector of extension cable) |
Display / output unit — 1 model
| Exact model | Listed supply / converter condition | Listed judgment output | Listed alarm output | Listed voltage output | Listed current output / source status | Listed response settings | Listed display | Listed connection |
|---|---|---|---|---|---|---|---|---|
| BD-A1 | 10-30VDC@(=) ±10% (When connecting BD-C Series communication converter, 12-30VDC@(=)) | NPN or PNP open collector output (Load current: Max. 100mA) | NPN or PNP open collector output (Load current: Max. 100mA) | -5 - 5 V, 0 - 5 V, 1 - 5 V (resistance: 100 Ω, ± 0.05% F.S., at 10 V) | Source review required: malformed native current-output field | 0.33, 0.5, 1, 2, 5 ms (5-step adjustment) | Dual display by 6-digit, 11-segment LED | Connector type |
Communication module — 1 model
| Exact model | Listed communication | Listed communication speed | Listed supply source | Listed consumption | Listed indicators |
|---|---|---|---|---|---|
| BD-CRS | RS-232C, RS-485 | 9600, 19200, 38400, 115200bps (default) | Using power from the amplifier unit. | Max. 2.3W | 4 LED status indicators |
Values and qualifiers are reproduced from native model descriptions, not inferred from suffixes. A maximum measurement range is not a guarantee of the same linearity across that entire interval: retain each stated interval and condition. Resolution, linearity and display increment are distinct and must not be substituted for one another. Power supplied by the amplifier is not treated as a direct DC input to a head. The display/output unit lists a different supply condition when a BD-C converter is connected; that condition is retained. One malformed current-output field is flagged for source review rather than silently corrected. Not specified in listing means absent or incomplete source data. Laser classes and protection exceptions are listed source data, not an independent safety certification; follow the exact manufacturer documentation for installation and use. Confirm system compatibility and ordering options on each exact model page and applicable manufacturer documentation. Existing product records, listings and content remain unchanged.