Shop ProductsView all categories →

Compare LIDAR Models

Compare all six current visible native LSE2, LSE3 and LSC listings. The same six exact models appear in both tables so scanning characteristics can be compared separately from supply, outputs and interfaces.

Scanning characteristics

Exact modelListed monitoring zone / native formatListed target-size criterion / source statusListed object reflectivityListed scan frequencyListed response / monitoring-time conditionListed aperture angleListed angular resolution
LSC-C10CT3-ET0.05 ~ 10 mAt detection distance of 8 m: ≈ 121 mmMin. 4%15 HzTyp. 67 ms270°0.33°
LSC-C25CT3-ET0.05 ~ 25 mAt detection distance of 8 m: ≈ 121 mmMin. 4%15 HzTyp. 67 ms270°0.33°
LSC-C5CT3-ET0.05 ~ 5 mSource review required: target criterion at 8 m exceeds listed monitoring limit 5 mMin. 4%15 HzTyp. 67 ms270°0.33°
LSE2-A5R2-ET≤ 5.6 × 5.6 mOFF, 5, 8, 10, 15, 20, 25, 30, 35, 40 cmMin. 2%25 Hz≤ 50 ms + monitoring time90°0.25 °
LSE3-4A10R2-ET0.3×0.3 ~ 10×10 mDetection distance of 3m : 2.1×2.1×2.1 cm, Detection distance of 5m : 3.5×3.5×3.5 cm, Detection distance of 10m : 7.0×7.0×7.0 cmMin. 2%15 Hz≤ 20 to 80ms + monitoring time90°0.4°
LSE3-4A5R2-ET0.3×0.3 ~ 5.6×5.6 mDetection distance of 3m : 2.1×2.1×2.1 cm, Detection distance of 5m : 3.5×3.5×3.5 cmMin. 2%15 Hz≤ 20 to 80ms + monitoring time90°0.4°

Electrical and interface characteristics

Exact modelListed supplyListed output / load conditionsListed interfaceListed laser classes by source contextListed environment of use
LSC-C10CT3-ET9-28VDC@(=)NPN-PNP open collector output setting (software)EthernetSingle listed laser: CLASS 1; installation laser not separately specifiedIndoor
LSC-C25CT3-ET9-28VDC@(=)NPN-PNP open collector output setting (software)EthernetSingle listed laser: CLASS 1; installation laser not separately specifiedIndoor
LSC-C5CT3-ET9-28VDC@(=)NPN-PNP open collector output setting (software)EthernetSingle listed laser: CLASS 1; installation laser not separately specifiedIndoor
LSE2-A5R2-ET24VDC @(=)PhotoMOS relay output: 2; Resistive load: 35 VDC@(=)/ 24 VAC~, ≤ 80 mAEthernetDetection: CLASS 1; Installation: CLASS 3RNot specified in listing
LSE3-4A10R2-ET10 ~ 35 VDC @(=)PhotoMOS relay output: 2; Resistive load: 35 VDC@(=)/ 24 VAC~, ≤ 80 mAEthernetDetection: CLASS 1; Installation: CLASS 3RNot specified in listing
LSE3-4A5R2-ET10 ~ 35 VDC @(=)PhotoMOS relay output: 2; Resistive load: 35 VDC@(=)/ 24 VAC~, ≤ 80 mAEthernetDetection: CLASS 1; Installation: CLASS 3RNot specified in listing

Values and conditions come from each exact native listing; no specification is inferred from a model suffix. Monitoring zones retain their original area or distance format: do not convert an area extent into a radial detection range. Target-size entries can be settings or criteria at specified distances, not a universal object-detection guarantee. One listing gives a target criterion beyond its own monitoring limit; that field is flagged rather than promoted as a verified detection specification. Response values that include monitoring time retain that condition. Detection and installation laser classes are kept separate wherever the source distinguishes them; a single listed laser class is not assumed to describe an unlisted installation laser. No safety certification, protective-device suitability or interoperability is inferred from these listings. Confirm exact manufacturer documentation before selection, installation and use. Not specified in listing means an absent field or native dash, not proof that an option is unavailable. Existing product records, content and listings remain unchanged.