Compare LIDAR Models
Compare all six current visible native LSE2, LSE3 and LSC listings. The same six exact models appear in both tables so scanning characteristics can be compared separately from supply, outputs and interfaces.
Scanning characteristics
| Exact model | Listed monitoring zone / native format | Listed target-size criterion / source status | Listed object reflectivity | Listed scan frequency | Listed response / monitoring-time condition | Listed aperture angle | Listed angular resolution |
|---|---|---|---|---|---|---|---|
| LSC-C10CT3-ET | 0.05 ~ 10 m | At detection distance of 8 m: ≈ 121 mm | Min. 4% | 15 Hz | Typ. 67 ms | 270° | 0.33° |
| LSC-C25CT3-ET | 0.05 ~ 25 m | At detection distance of 8 m: ≈ 121 mm | Min. 4% | 15 Hz | Typ. 67 ms | 270° | 0.33° |
| LSC-C5CT3-ET | 0.05 ~ 5 m | Source review required: target criterion at 8 m exceeds listed monitoring limit 5 m | Min. 4% | 15 Hz | Typ. 67 ms | 270° | 0.33° |
| LSE2-A5R2-ET | ≤ 5.6 × 5.6 m | OFF, 5, 8, 10, 15, 20, 25, 30, 35, 40 cm | Min. 2% | 25 Hz | ≤ 50 ms + monitoring time | 90° | 0.25 ° |
| LSE3-4A10R2-ET | 0.3×0.3 ~ 10×10 m | Detection distance of 3m : 2.1×2.1×2.1 cm, Detection distance of 5m : 3.5×3.5×3.5 cm, Detection distance of 10m : 7.0×7.0×7.0 cm | Min. 2% | 15 Hz | ≤ 20 to 80ms + monitoring time | 90° | 0.4° |
| LSE3-4A5R2-ET | 0.3×0.3 ~ 5.6×5.6 m | Detection distance of 3m : 2.1×2.1×2.1 cm, Detection distance of 5m : 3.5×3.5×3.5 cm | Min. 2% | 15 Hz | ≤ 20 to 80ms + monitoring time | 90° | 0.4° |
Electrical and interface characteristics
| Exact model | Listed supply | Listed output / load conditions | Listed interface | Listed laser classes by source context | Listed environment of use |
|---|---|---|---|---|---|
| LSC-C10CT3-ET | 9-28VDC@(=) | NPN-PNP open collector output setting (software) | Ethernet | Single listed laser: CLASS 1; installation laser not separately specified | Indoor |
| LSC-C25CT3-ET | 9-28VDC@(=) | NPN-PNP open collector output setting (software) | Ethernet | Single listed laser: CLASS 1; installation laser not separately specified | Indoor |
| LSC-C5CT3-ET | 9-28VDC@(=) | NPN-PNP open collector output setting (software) | Ethernet | Single listed laser: CLASS 1; installation laser not separately specified | Indoor |
| LSE2-A5R2-ET | 24VDC @(=) | PhotoMOS relay output: 2; Resistive load: 35 VDC@(=)/ 24 VAC~, ≤ 80 mA | Ethernet | Detection: CLASS 1; Installation: CLASS 3R | Not specified in listing |
| LSE3-4A10R2-ET | 10 ~ 35 VDC @(=) | PhotoMOS relay output: 2; Resistive load: 35 VDC@(=)/ 24 VAC~, ≤ 80 mA | Ethernet | Detection: CLASS 1; Installation: CLASS 3R | Not specified in listing |
| LSE3-4A5R2-ET | 10 ~ 35 VDC @(=) | PhotoMOS relay output: 2; Resistive load: 35 VDC@(=)/ 24 VAC~, ≤ 80 mA | Ethernet | Detection: CLASS 1; Installation: CLASS 3R | Not specified in listing |
Values and conditions come from each exact native listing; no specification is inferred from a model suffix. Monitoring zones retain their original area or distance format: do not convert an area extent into a radial detection range. Target-size entries can be settings or criteria at specified distances, not a universal object-detection guarantee. One listing gives a target criterion beyond its own monitoring limit; that field is flagged rather than promoted as a verified detection specification. Response values that include monitoring time retain that condition. Detection and installation laser classes are kept separate wherever the source distinguishes them; a single listed laser class is not assumed to describe an unlisted installation laser. No safety certification, protective-device suitability or interoperability is inferred from these listings. Confirm exact manufacturer documentation before selection, installation and use. Not specified in listing means an absent field or native dash, not proof that an option is unavailable. Existing product records, content and listings remain unchanged.